H3C交接机风扇报警:Fan 1 airflow direction is not preferred on slot 1(port-to-power、power to port)
H3C交接机风扇报警:Fan 1 airflow direction is not preferred on slot 1(port-to-power、power to port)
H3C S5830V2[S5820V2]系列以太网交换机 故障处理手册-6W101-整本手册.pdf
报错信息:
%Jan 2 03:20:47:802 2011 H3C DEV/1/FAN_DIRECTION_NOT_PREFERRED: Fan 1 airflow direction is not preferred on slot 1, please check it.
%Jan 2 03:20:47:803 2011 H3C DEV/1/FAN_DIRECTION_NOT_PREFERRED: Fan 2 airflow direction is not preferred on slot 1, please check it.
处理方式:
在视图模式下输入命令:fan prefer-direction slot 2 port-to-power
分别修改两个风扇的风道就OK了。
最后dis fan 查看风扇状态即可。
把风扇吹风风向调为一致。即风扇的转向调为一致。
fan prefer-direction slot 1 port-to-power
fan prefer-direction slot 2 port-to-power
fan prefer-direction slot 3 port-to-power
[H3C] fan prefer-direction slot 1 ?
port-to-power From port to power
power-to-port From power to port
[H3C]fan prefer-direction slot 1
显示设备风扇的工作状态 display fan [ fan-id ]
<H3C-SW>display fan
Slot 1:
Fan 1:
State : Normal
Airflow Direction: Port-to-power
Prefer Airflow Direction: Port-to-power
Fan 2:
State : Normal
Airflow Direction: Port-to-power
Prefer Airflow Direction: Port-to-power
<H3C-SW>
<H3C-SW>system-view
System View: return to User View with Ctrl+Z.
[H3C-SW]fan
[H3C-SW]fan ?
prefer-direction Set the preferred fan direction
[H3C-SW]fan pre
[H3C-SW]fan prefer-direction ?
slot Specify the slot number
[H3C-SW]fan prefer-direction slot ?
<1> Slot number
[H3C-SW]fan prefer-direction slot 1 ?
port-to-power From port to power
power-to-port From power to port
[H3C-SW]fan prefer-direction slot 1 port-to-power
#配置此命令后,告警消失。
[H3C-SW]fan prefer-direction slot ?
<1> Slot number
[H3C-SW]
[H3C-SW]dis fan
Slot 1:
Fan 1:
State : Normal
Airflow Direction: Port-to-power
Prefer Airflow Direction: Port-to-power
Fan 2:
State : Normal
Airflow Direction: Port-to-power
Prefer Airflow Direction: Port-to-power
[H3C-SW]
远程管理(列表、list、全)远程telnetlist、vtylist、consolelist、sshlist、httplist、weblist、httpslist
http://www.zh-cjh.com/wenzhangguilei/2441.html
文章归类、所有文章列表、LISTLIST
http://www.zh-cjh.com/wangzhangonggao/2195.html
2、本资源基本为原创,部分来源其他付费资源平台或互联网收集,如有侵权请联系及时处理。
3、本站大部分文章的截图来源实验测试环境,请不要在生产环境中随意模仿,以免带来灾难性后果。
转载请保留出处: www.zh-cjh.com珠海陈坚浩博客 » H3C交接机风扇报警:Fan 1 airflow direction is not preferred on slot 1(port-to-power、power to port)
作者: cjh
手机扫一扫,手机上查看此文章: |
一切源于价值!
其他 模板文件不存在: ./template/plugins/comment/pc/index.htm